Review:
Aeotec Multisensor 6
Parameters:
With parameters you can change settings of the sensor itself such as the update time and sensitivity of the motion sensor. Most controllers have this built-in as standard.
2) Wake up after 10 minutes when you put the power back on.
Default setting: 0
Available setting: 0 (Off), 1 (On)
3) Out of time of the PIR
Default setting: 240 (4 min.)
Available setting: 10 ~ 3600
4) Sensitivity of PIR
Default setting: 5 (high)
Available setting: 1 ~ 5 (Low> High)
5) Basic command
Default setting: 1
Available setting: 1 (Basic Set CC.), 2 (Sensor Binary Report CC.)
8) Time out after waking up
Default setting: 16
Available setting: 1
39) Low battery level setting
Default setting: 20 (5)
Available setting: 10 ~ 50 (send signal if it is lower than set value)
40) Threshold reporting
Default setting: 0
Available setting: 0 (Off), 1 (On)
41) Threshold of temperature
Default setting: 20 (2 ℃)
Available setting: click here to download an excel where you can calculate this
42) Threshold of humidity
Default setting: 10 (%)
Available setting: 1 ~ 100
43) Threshold from LUX
Default setting: 100 (lux)
45) Threshold from LUX
Default setting: 2
46) Low temperature alarm
Default setting: 0
Available setting: 1 (Off), 2 (On, sends a report at -15 ℃)