Review:
Neo Coolcam Door sensor
Parameters:
With parameters you can change things about the sensor itself, such as the update time and sensitivity of the motion sensor. Most controllers have this baked in by default.
1. LED on/off?
With this parameter you can set whether the LED should be on or off.
Default value: 1
Available settings: 0 (off), 1 (on)
2. Binary Sensor Report Enable<
You can determine whether or not the sensor has to transmit a value.
Default setting: 1
Available setting: 0 (no value), 1 (value)
3. Temperature offset
You can set how many degrees the measured temperature should deviate.
Default setting: 0
Available setting: -120 > 120 (value x 0.1 degrees)
4. Humidity offset
You can set how much RH% the measured humidity should deviate.
Default setting: 0
Available setting: -120 > 120 (value x 0.1 RH%)
5. Deviation value of temperature
With this you can set at how much difference (relative to the previous value) in temperature an update should be sent to the controller.
Default setting: 10
Available setting: 0 > 100 (value x 0.1 degrees)
6. Deviation value of temperature
With this you can set at how much difference (compared to the previous value) in humidity an update should be sent to the controller.
Default setting: 10
Available setting: 0 > 100 (value x 0.1 RH%)
7. Basic delay (off command)
Default setting: 30
Available setting: 0 > 3000 (second)
8. Sensor interval
Default setting: 180
Available setting: 0 > 30000 (higher is slower)