Parameters:

1) Relay type
Default setting: 0
Available setting: 0 (Normally open), 1 (Normally closed)

10) Auto off (LED)
Default settings: 0
Available settings: 0 (off), 30 - 32535 ​​= 30 - 32535 ​​seconds (after power on)

11) Auto on (LED)
Default settings: 0
Available settings: 0 (off), 30 - 32535 ​​= 30 - 32535 ​​seconds (after turned off)

12) Auto off (Relay)
Default settings: 0
Available settings: 0 (off), 30 - 32535 ​​= 30 - 32535 ​​seconds (after power on)

13) Auto on (Relay)
Default settings: 0
Available settings: 0 (off), 30 - 32535 ​​= 30 - 32535 ​​seconds (after turned off)

30) Memorize status after power failure
Default setting: 2
Available setting: 0 (Turn off), 1 (Turn on)

40) Current threshold reporting
Setting to determine at how much change of the energy level (%) a report should be sent to the controller.
Default setting: 10 (%)
Available setting: 0 (off), 1-100 (%)

42) Flow reporting time
Default setting: 0
Available setting: 0 (off), 30 - 32535 ​​= 30 - 32535 ​​seconds

60) Switch relay button on/off in touch
Default settings: 0
Available settings: 0 (off), 1 (on)

70) Overload protection
Default setting: 2300
Available setting: 1 - 2300 (W), 0 (not active)